Doubly fed induction machine : (Record no. 42374)
[ view plain ]
000 -LEADER | |
---|---|
fixed length control field | 16502nam a2201189 i 4500 |
001 - CONTROL NUMBER | |
control field | 6047757 |
003 - CONTROL NUMBER IDENTIFIER | |
control field | IEEE |
005 - DATE AND TIME OF LATEST TRANSACTION | |
control field | 20191218152122.0 |
006 - FIXED-LENGTH DATA ELEMENTS--ADDITIONAL MATERIAL CHARACTERISTICS | |
fixed length control field | m o d |
007 - PHYSICAL DESCRIPTION FIXED FIELD--GENERAL INFORMATION | |
fixed length control field | cr |n||||||||| |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
fixed length control field | 151221s2011 njua ob 001 eng d |
020 ## - INTERNATIONAL STANDARD BOOK NUMBER | |
International Standard Book Number | 9781118104965 |
Qualifying information | ebook |
020 ## - INTERNATIONAL STANDARD BOOK NUMBER | |
Canceled/invalid ISBN | 9780470768655 |
Qualifying information | |
020 ## - INTERNATIONAL STANDARD BOOK NUMBER | |
Canceled/invalid ISBN | 111810496X |
Qualifying information | electronic |
024 7# - OTHER STANDARD IDENTIFIER | |
Standard number or code | 10.1002/9781118104965 |
Source of number or code | doi |
035 ## - SYSTEM CONTROL NUMBER | |
System control number | (CaBNVSL)mat06047757 |
035 ## - SYSTEM CONTROL NUMBER | |
System control number | (IDAMS)0b00006481692cdd |
040 ## - CATALOGING SOURCE | |
Original cataloging agency | CaBNVSL |
Language of cataloging | eng |
Description conventions | rda |
Transcribing agency | CaBNVSL |
Modifying agency | CaBNVSL |
050 #4 - LIBRARY OF CONGRESS CALL NUMBER | |
Classification number | TK1541 |
Item number | .D68 2011eb |
082 04 - DEWEY DECIMAL CLASSIFICATION NUMBER | |
Classification number | 621.312136 |
Edition number | 22 |
245 00 - TITLE STATEMENT | |
Title | Doubly fed induction machine : |
Remainder of title | modeling and control for wind energy generation applications / |
Statement of responsibility, etc. | by Gonzalo Abad ... [et al.]. |
264 #1 - PRODUCTION, PUBLICATION, DISTRIBUTION, MANUFACTURE, AND COPYRIGHT NOTICE | |
Place of production, publication, distribution, manufacture | Oxford : |
Name of producer, publisher, distributor, manufacturer | Wiley-Blackwell, |
Date of production, publication, distribution, manufacture, or copyright notice | 2011. |
264 #2 - PRODUCTION, PUBLICATION, DISTRIBUTION, MANUFACTURE, AND COPYRIGHT NOTICE | |
Place of production, publication, distribution, manufacture | [Piscataqay, New Jersey] : |
Name of producer, publisher, distributor, manufacturer | IEEE Xplore, |
Date of production, publication, distribution, manufacture, or copyright notice | [2011] |
300 ## - PHYSICAL DESCRIPTION | |
Extent | 1 PDF (xiv, 625 pages) : |
Other physical details | illustrations. |
336 ## - CONTENT TYPE | |
Content type term | text |
Source | rdacontent |
337 ## - MEDIA TYPE | |
Media type term | electronic |
Source | isbdmedia |
338 ## - CARRIER TYPE | |
Carrier type term | online resource |
Source | rdacarrier |
490 1# - SERIES STATEMENT | |
Series statement | IEEE Press series on power engineering ; |
Volume/sequential designation | 84 |
500 ## - GENERAL NOTE | |
General note | In Wiley online library |
505 0# - FORMATTED CONTENTS NOTE | |
Formatted contents note | Preface xiii -- 1 Introduction to A Wind Energy Generation System 1 -- 1.1 Introduction 1 -- 1.2 Basic Concepts of a Fixed Speed Wind Turbine (FSWT) 2 -- 1.2.1 Basic Wind Turbine Description 2 -- 1.2.2 Power Control of Wind Turbines 5 -- 1.2.3 Wind Turbine Aerodynamics 7 -- 1.2.4 Example of a Commercial Wind Turbine 9 -- 1.3 Variable Speed Wind Turbines (VSWTs) 10 -- 1.3.1 Modeling of Variable Speed Wind Turbine 11 -- 1.3.2 Control of a Variable Speed Wind Turbine 15 -- 1.3.3 Electrical System of a Variable Speed Wind Turbine 22 -- 1.4 Wind Energy Generation System Based on DFIM VSWT 25 -- 1.4.1 Electrical Configuration of a VSWT Based on the DFIM 25 -- 1.4.2 Electrical Configuration of a Wind Farm 33 -- 1.4.3 WEGS Control Structure 34 -- 1.5 Grid Code Requirements 39 -- 1.5.1 Frequency and Voltage Operating Range 40 -- 1.5.2 Reactive Power and Voltage Control Capability 41 -- 1.5.3 Power Control 43 -- 1.5.4 Power System Stabilizer Function 45 -- 1.5.5 Low Voltage Ride Through (LVRT) 46 -- 1.6 Voltage Dips and LVRT 46 -- 1.6.1 Electric Power System 47 -- 1.6.2 Voltage Dips 50 -- 1.6.3 Spanish Verification Procedure 55 -- 1.7 VSWT Based on DFIM Manufacturers 57 -- 1.7.1 Industrial Solutions: Wind Turbine Manufacturers 57 -- 1.7.2 Modeling a 2.4 MW Wind Turbine 72 -- 1.7.3 Steady State Generator and Power Converter Sizing 79 -- 1.8 Introduction to the Next Chapters 83 -- Bibliography 85 -- 2 Back-to-Back Power Electronic Converter 87 -- 2.1 Introduction 87 -- 2.2 Back-to-Back Converter based on Two-Level VSC Topology 88 -- 2.2.1 Grid Side System 89 -- 2.2.2 Rotor Side Converter and dv/dt Filter 96 -- 2.2.3 DC Link 99 -- 2.2.4 Pulse Generation of the Controlled Switches 101 -- 2.3 Multilevel VSC Topologies 114 -- 2.3.1 Three-Level Neutral Point Clamped VSC Topology (3L-NPC) 116 -- 2.4 Control of Grid Side System 133 -- 2.4.1 Steady State Model of the Grid Side System 133 -- 2.4.2 Dynamic Modeling of the Grid Side System 139 -- 2.4.3 Vector Control of the Grid Side System 143. |
505 8# - FORMATTED CONTENTS NOTE | |
Formatted contents note | 2.5 Summary 152 -- References 153 -- 3 Steady State of the Doubly Fed Induction Machine 155 -- 3.1 Introduction 155 -- 3.2 Equivalent Electric Circuit at Steady State 156 -- 3.2.1 Basic Concepts on DFIM 156 -- 3.2.2 Steady State Equivalent Circuit 158 -- 3.2.3 Phasor Diagram 163 -- 3.3 Operation Modes Attending to Speed and Power Flows 165 -- 3.3.1 Basic Active Power Relations 165 -- 3.3.2 Torque Expressions 168 -- 3.3.3 Reactive Power Expressions 170 -- 3.3.4 Approximated Relations Between Active Powers, Torque, and Speeds 170 -- 3.3.5 Four Quadrant Modes of Operation 171 -- 3.4 Per Unit Transformation 173 -- 3.4.1 Base Values 175 -- 3.4.2 Per Unit Transformation of Magnitudes and Parameters 176 -- 3.4.3 Steady State Equations of the DFIM in p.u 177 -- 3.4.4 Example 3.1: Parameters of a 2 MW DFIM 179 -- 3.4.5 Example 3.2: Parameters of Different Power DFIM 180 -- 3.4.6 Example 3.3: Phasor Diagram of a 2 MW DFIM and p.u. Analysis 181 -- 3.5 Steady State Curves: Performance Evaluation 184 -- 3.5.1 Rotor Voltage Variation: Frequency, Amplitude, and Phase Shift 185 -- 3.5.2 Rotor Voltage Variation: Constant Voltage-Frequency (V-F) Ratio 192 -- 3.5.3 Rotor Voltage Variation: Control of Stator Reactive Power and Torque 195 -- 3.6 Design Requirements for the DFIM in Wind Energy Generation Applications 202 -- 3.7 Summary 207 -- References 208 -- 4 Dynamic Modeling of the Doubly Fed Induction Machine 209 -- 4.1 Introduction 209 -- 4.2 Dynamic Modeling of the DFIM 210 -- 4.2.1 ab Model 212 -- 4.2.2 dq Model 214 -- 4.2.3 State-Space Representation of ab Model 216 -- 4.2.4 State-Space Representation of dq Model 229 -- 4.2.5 Relation Between the Steady State Model and the Dynamic Model 234 -- 4.3 Summary 238 -- References 238 -- 5 Testing the DFIM 241 -- 5.1 Introduction 241 -- 5.2 Off-Line Estimation of DFIM Model Parameters 242 -- 5.2.1 Considerations About the Model Parameters of the DFIM 243 -- 5.2.2 Stator and Rotor Resistances Estimation by VSC 245 -- 5.2.3 Leakage Inductances Estimation by VSC 250. |
505 8# - FORMATTED CONTENTS NOTE | |
Formatted contents note | 5.2.4 Magnetizing Inductance and Iron Losses Estimation with No-Load Test by VSC 256 -- 5.3 Summary 262 -- References 262 -- 6 Analysis of the DFIM Under Voltage Dips 265 -- 6.1 Introduction 265 -- 6.2 Electromagnetic Force Induced in the Rotor 266 -- 6.3 Normal Operation 267 -- 6.4 Three-Phase Voltage Dips 268 -- 6.4.1 Total Voltage Dip, Rotor Open-Circuited 268 -- 6.4.2 Partial Voltage Dip, Rotor Open-Circuited 273 -- 6.5 Asymmetrical Voltage Dips 278 -- 6.5.1 Fundamentals of the Symmetrical Component Method 278 -- 6.5.2 Symmetrical Components Applied to the DFIM 281 -- 6.5.3 Single-Phase Dip 283 -- 6.5.4 Phase-to-Phase Dip 286 -- 6.6 Influence of the Rotor Currents 290 -- 6.6.1 Influence of the Rotor Current in a Total Three-Phase Voltage Dip 291 -- 6.6.2 Rotor Voltage in a General Case 294 -- 6.7 DFIM Equivalent Model During Voltage Dips 297 -- 6.7.1 Equivalent Model in Case of Linearity 297 -- 6.7.2 Equivalent Model in Case of Nonlinearity 299 -- 6.7.3 Model of the Grid 300 -- 6.8 Summary 300 -- References 301 -- 7 Vector Control Strategies for Grid-Connected DFIM Wind Turbines 303 -- 7.1 Introduction 303 -- 7.2 Vector Control 304 -- 7.2.1 Calculation of the Current References 305 -- 7.2.2 Limitation of the Current References 307 -- 7.2.3 Current Control Loops 308 -- 7.2.4 Reference Frame Orientations 311 -- 7.2.5 Complete Control System 313 -- 7.3 Small Signal Stability of the Vector Control 314 -- 7.3.1 Influence of the Reference Frame Orientation 314 -- 7.3.2 Influence of the Tuning of the Regulators 320 -- 7.4 Vector Control Behavior Under Unbalanced Conditions 327 -- 7.4.1 Reference Frame Orientation 328 -- 7.4.2 Saturation of the Rotor Converter 328 -- 7.4.3 Oscillations in the Stator Current and in the Electromagnetic Torque 328 -- 7.5 Vector Control Behavior Under Voltage Dips 331 -- 7.5.1 Small Dips 333 -- 7.5.2 Severe Dips 336 -- 7.6 Control Solutions for Grid Disturbances 340 -- 7.6.1 Demagnetizing Current 340 -- 7.6.2 Dual Control Techniques 346 -- 7.7 Summary 358. |
505 8# - FORMATTED CONTENTS NOTE | |
Formatted contents note | References 360 -- 8 Direct Control of the Doubly Fed Induction Machine 363 -- 8.1 Introduction 363 -- 8.2 Direct Torque Control (DTC) of the Doubly Fed Induction Machine 364 -- 8.2.1 Basic Control Principle 365 -- 8.2.2 Control Block Diagram 371 -- 8.2.3 Example 8.1: Direct Torque Control of a 2 MW DFIM 377 -- 8.2.4 Study of Rotor Voltage Vector Effect in the DFIM 379 -- 8.2.5 Example 8.2: Spectrum Analysis in Direct Torque Control of a 2 MW DFIM 384 -- 8.2.6 Rotor Flux Amplitude Reference Generation 386 -- 8.3 Direct Power Control (DPC) of the Doubly Fed Induction Machine 387 -- 8.3.1 Basic Control Principle 387 -- 8.3.2 Control Block Diagram 390 -- 8.3.3 Example 8.3: Direct Power Control of a 2 MW DFIM 395 -- 8.3.4 Study of Rotor Voltage Vector Effect in the DFIM 395 -- 8.4 Predictive Direct Torque Control (P-DTC) of the Doubly Fed Induction Machine at Constant Switching Frequency 399 -- 8.4.1 Basic Control Principle 399 -- 8.4.2 Control Block Diagram 402 -- 8.4.3 Example 8.4: Predictive Direct Torque Control of 15kW and 2 MW DFIMs at 800 Hz Constant -- Switching Frequency 411 -- 8.4.4 Example 8.5: Predictive Direct Torque Control of a 15kW DFIM at 4 kHz Constant Switching Frequency 415 -- 8.5 Predictive Direct Power Control (P-DPC) of the Doubly Fed Induction Machine at Constant Switching Frequency 416 -- 8.5.1 Basic Control Principle 417 -- 8.5.2 Control Block Diagram 419 -- 8.5.3 Example 8.6: Predictive Direct Power Control of a 15 kW DFIM at 1 kHz Constant Switching Frequency 424 -- 8.6 Multilevel Converter Based Predictive Direct Power and Direct Torque Control of the Doubly Fed Induction Machine at Constant Switching Frequency 425 -- 8.6.1 Introduction 425 -- 8.6.2 Three-Level NPC VSC Based DPC of the DFIM 428 -- 8.6.3 Three-Level NPC VSC Based DTC of the DFIM 447 -- 8.7 Control Solutions for Grid Voltage Disturbances, Based on Direct Control Techniques 451 -- 8.7.1 Introduction 451 -- 8.7.2 Control for Unbalanced Voltage Based on DPC 452 -- 8.7.3 Control for Unbalanced Voltage Based on DTC 460. |
505 8# - FORMATTED CONTENTS NOTE | |
Formatted contents note | 8.7.4 Control for Voltage Dips Based on DTC 467 -- 8.8 Summary 473 -- References 474 -- 9 Hardware Solutions for LVRT 479 -- 9.1 Introduction 479 -- 9.2 Grid Codes Related to LVRT 479 -- 9.3 Crowbar 481 -- 9.3.1 Design of an Active Crowbar 484 -- 9.3.2 Behavior Under Three-Phase Dips 486 -- 9.3.3 Behavior Under Asymmetrical Dips 488 -- 9.3.4 Combination of Crowbar and Software Solutions 490 -- 9.4 Braking Chopper 492 -- 9.4.1 Performance of a Braking Chopper Installed Alone 492 -- 9.4.2 Combination of Crowbar and Braking Chopper 493 -- 9.5 Other Protection Techniques 495 -- 9.5.1 Replacement Loads 495 -- 9.5.2 Wind Farm Solutions 496 -- 9.6 Summary 497 -- References 498 -- 10 Complementary Control Issues: Estimator Structures and Start-Up of Grid-Connected DFIM 501 -- 10.1 Introduction 501 -- 10.2 Estimator and Observer Structures 502 -- 10.2.1 General Considerations 502 -- 10.2.2 Stator Active and Reactive Power Estimation for Rotor Side DPC 503 -- 10.2.3 Stator Flux Estimator from Stator Voltage for Rotor Side Vector Control 503 -- 10.2.4 Stator Flux Synchronization from Stator Voltage for Rotor Side Vector Control 506 -- 10.2.5 Stator and Rotor Fluxes Estimation for Rotor Side DPC, DTC, and Vector Control 507 -- 10.2.6 Stator and Rotor Flux Full Order Observer 508 -- 10.3 Start-up of the Doubly Fed Induction Machine Based Wind Turbine 512 -- 10.3.1 Encoder Calibration 514 -- 10.3.2 Synchronization with the Grid 518 -- 10.3.3 Sequential Start-up of the DFIM Based Wind Turbine 523 -- 10.4 Summary 534 -- References 535 -- 11 Stand-Alone DFIM Based Generation Systems 537 -- 11.1 Introduction 537 -- 11.1.1 Requirements of Stand-alone DFIM Based System 537 -- 11.1.2 Characteristics of DFIM Supported by DC Coupled Storage 540 -- 11.1.3 Selection of Filtering Capacitors 541 -- 11.2 Mathematical Description of the Stand-Alone DFIM System 544 -- 11.2.1 Model of Stand-alone DFIM 544 -- 11.2.2 Model of Stand-alone DFIM Fed from Current Source 549 -- 11.2.3 Polar Frame Model of Stand-alone DFIM 551. |
505 8# - FORMATTED CONTENTS NOTE | |
Formatted contents note | 11.2.4 Polar Frame Model of Stand-alone DFIM Fed from Current Source 554 -- 11.3 Stator Voltage Control 558 -- 11.3.1 Amplitude and Frequency Control by the Use of PLL 558 -- 11.3.2 Voltage Asymmetry Correction During Unbalanced Load Supply 567 -- 11.3.3 Voltage Harmonics Reduction During Nonlinear Load Supply 569 -- 11.4 Synchronization Before Grid Connection By Superior PLL 573 -- 11.5 Summary 576 -- References 577 -- 12 New Trends on Wind Energy Generation 579 -- 12.1 Introduction 579 -- 12.2 Future Challenges for Wind Energy Generation: What must be Innovated 580 -- 12.2.1 Wind Farm Location 580 -- 12.2.2 Power, Efficiency, and Reliability Increase 582 -- 12.2.3 Electric Grid Integration 583 -- 12.2.4 Environmental Concerns 583 -- 12.3 Technological Trends: How They Can be Achieved 584 -- 12.3.1 Mechanical Structure of the Wind Turbine 585 -- 12.3.2 Power Train Technology 586 -- 12.4 Summary 599 -- References 600 -- Appendix 603 -- A.1 Space Vector Representation 603 -- A.1.1 Space Vector Notation 603 -- A.1.2 Transformations to Different Reference Frames 606 -- A.1.3 Power Expressions 609 -- A.2 Dynamic Modeling of the DFIM Considering the Iron Losses 610 -- A.2.1 ab Model 611 -- A.2.2 dq Model 614 -- A.2.3 State-Space Representation of ab Model 616 -- References 618 -- Index 619 -- The IEEE Press Series on Power Engineering. |
506 1# - RESTRICTIONS ON ACCESS NOTE | |
Terms governing access | Restricted to subscribers or individual electronic text purchasers. |
520 ## - SUMMARY, ETC. | |
Summary, etc. | A practical, hands-on guide to capturing the potential of DFIM technologyDoubly Fed Induction Machine (DFIM)-based wind turbines have proven to be a cost-effective, efficient, and reliable method for generating power. Readers interested in DFIM technology can turn to this text to discover not only the current state of the technology and future directions for research and development, but also learn the tools they need to devise their own innovations and solutions.Doubly Fed Induction Machine offers clear mathematical descriptions of basic dynamic DFIM models as well as a detailed steady-state analysis. The authors provide a more sophisticated model of a DFIM that takes into account grid disturbances such as voltage dips and balance disruptions.The second part of the book surveys DFIM control strategies. Readers will learn about standard solutions used by wind turbine manufacturers, new developments designed to improve the behavior of high-power wind turbines, as well as hardware-based solutions that address faulty grid scenarios. The book concludes with a forecast of the future of DFIMs.This book is an ideal, practical reference for engineers, researches, and students interested in fully learning the power generation capabilities of DFIM technology. This book helps readers grasp and apply complex concepts by using numerous aids throughout including:. Diagrams and graphs. Step-by-step calculations. Illustrations and photos of DFIM components and systems. |
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE | |
Additional physical form available note | Also available in print. |
538 ## - SYSTEM DETAILS NOTE | |
System details note | Mode of access: World Wide Web |
588 ## - SOURCE OF DESCRIPTION NOTE | |
Source of description note | Description based on PDF viewed 12/21/2015. |
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
Topical term or geographic name entry element | Induction generators |
General subdivision | Mathematical models. |
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
Topical term or geographic name entry element | Induction generators |
General subdivision | Automatic control. |
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
Topical term or geographic name entry element | Wind turbines |
General subdivision | Equipment and supplies. |
655 #0 - INDEX TERM--GENRE/FORM | |
Genre/form data or focus term | Electronic books. |
695 ## - | |
-- | AC machines |
695 ## - | |
-- | Aerospace electronics |
695 ## - | |
-- | Blades |
695 ## - | |
-- | Capacitors |
695 ## - | |
-- | Computational modeling |
695 ## - | |
-- | Control systems |
695 ## - | |
-- | Current measurement |
695 ## - | |
-- | Differential equations |
695 ## - | |
-- | Electromagnetic forces |
695 ## - | |
-- | Electronics packaging |
695 ## - | |
-- | Energy storage |
695 ## - | |
-- | Equations |
695 ## - | |
-- | Estimation |
695 ## - | |
-- | Facsimile |
695 ## - | |
-- | Generators |
695 ## - | |
-- | Hardware |
695 ## - | |
-- | Ice |
695 ## - | |
-- | Indexes |
695 ## - | |
-- | Inductance |
695 ## - | |
-- | Induction machines |
695 ## - | |
-- | Iron |
695 ## - | |
-- | Machine vector control |
695 ## - | |
-- | Mathematical model |
695 ## - | |
-- | Poles and towers |
695 ## - | |
-- | Power control |
695 ## - | |
-- | Power conversion |
695 ## - | |
-- | Reliability |
695 ## - | |
-- | Resistance |
695 ## - | |
-- | Resistors |
695 ## - | |
-- | Rotors |
695 ## - | |
-- | Sensors |
695 ## - | |
-- | Shafts |
695 ## - | |
-- | Space stations |
695 ## - | |
-- | Stator windings |
695 ## - | |
-- | Stators |
695 ## - | |
-- | Steady-state |
695 ## - | |
-- | Switching frequency |
695 ## - | |
-- | Topology |
695 ## - | |
-- | Torque |
695 ## - | |
-- | Torque control |
695 ## - | |
-- | Voltage control |
695 ## - | |
-- | Voltage fluctuations |
695 ## - | |
-- | Voltage measurement |
695 ## - | |
-- | Warranties |
695 ## - | |
-- | Wind |
695 ## - | |
-- | Wind energy |
695 ## - | |
-- | Wind energy generation |
695 ## - | |
-- | Wind farms |
695 ## - | |
-- | Wind power generation |
695 ## - | |
-- | Wind turbines |
695 ## - | |
-- | Windings |
700 1# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Abad, G. |
Fuller form of name | (Gonzalo), |
Dates associated with a name | 1976- |
710 2# - ADDED ENTRY--CORPORATE NAME | |
Corporate name or jurisdiction name as entry element | IEEE Xplore (Online Service), |
Relator term | distributor. |
710 2# - ADDED ENTRY--CORPORATE NAME | |
Corporate name or jurisdiction name as entry element | John Wiley & Sons, |
Relator term | publisher. |
776 08 - ADDITIONAL PHYSICAL FORM ENTRY | |
Relationship information | Print version: |
International Standard Book Number | 9780470768655 |
830 #0 - SERIES ADDED ENTRY--UNIFORM TITLE | |
Uniform title | IEEE Press series on power engineering ; |
Volume/sequential designation | 84 |
856 42 - ELECTRONIC LOCATION AND ACCESS | |
Materials specified | Abstract with links to resource |
Uniform Resource Identifier | https://ieeexplore.ieee.org/xpl/bkabstractplus.jsp?bkn=6047757 |
No items available.